Description: Model 1:ECG90A 12-channel 12 lead ECGIntroductionsECG90A is an electrocardiograph collecting 12-lead ECG signal simultaneously and printing ECG waveform with thermal printing system, which features in, recording and displaying ECG waveform with manual or auto mode, measuring and diagnosing ECG waveform parameters automatically, prompting for “Lead off” and “Lack of paper”, optional interface languages(Chinese/English), case database management. Function 1)Sync collection for 12-lead ECG, adopt digital signal processing technology and get high-quality ECG waveform via power frequency filter, baseline filter and EMG filter of ECG signal.2)Particular and high-accurate digital filter eliminates baseline drift, no distortion to ECG waveform, greatly enhances anti-baseline drift capacity, convenient for waveform judgment.3)Display of 3/6/12-lead ECG, print mode, sensitivity, paper speed and filter state, etc. on one screen, convenient for contrastively diagnosing.4)Real-time and continuously record the clear and accurate ECG waveform and annotation character(including lead mark, sensitivity, paper speed and filter state, etc.).5)Adopt high-resolution thermal printing system(8 dot/mm), no need for any adjustments. Recording frequency: up to 150Hz. 6)With the functions of auto-analysis and auto-diagnosis for routine ECG parameters, provide measurement results and auto-diagnosis conclusion for HR, P-R interval, P Duration, QRS Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1), etc. which reduces the doctor’s burden.7)Optional SD card stores up to 100 cases, which is convenient for doctor to review case and statistic.8)In review mode, case waveform stored can be checked, measurement parameter and diagnosis information can be automatically analyzed.9)Two languages(Chinese or English) interface and report.10)Optional ECG-Sync software, connect with PC by USB2.0 interface to form a ECG workstation, collect real-time data to the software for analyzing and printing the report, and old cases stored in Electrocardiograph can be uploaded to PC.11)Power supply: AC/DC, and in optimal DC state, built-in rechargeable lithium battery can continuously work for 4-hour, print up to 90-minute and 150-ECG, which meets the requirements of visiting a patient at home and body examination. Rechargeable lithium battery is detachable, which is convenient for user to replace and charge in any time.Performance Input mode: floating and defibrillation protectionFrequency response: 0.05Hz ~ 150Hz(-3dB~+0.4dB)CMRR: >60dB, >100dB(add filter)Time constant:≥ 3.2sPatient leak current: <10µACalibration voltage: 1mVSensitivity: 5, 10, 20 mm/mV ±5%, standard sensitivity: 10mm/mV±2%Noise level: ≤15µVp-pInput circuit current: ≤50nAInput impedance: ≥50MΩSampling accuracy: 12-bitSafety classification: class I, type CF and defibrillation-proof applied partRecording mode: thermal printing systemMeasurement parameters: HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1)Paper size: 50mm(W)×20m(L)Sampling frequency: 1000HzPolarizing voltage: ±500mVEMG interference filter: 25Hz/35Hz (-3dB)Power frequency filter: AC 50Hz/60Hz(-20dB)Paper speed: Auto: 6.25, 12.5, 25, 50mm/s, ±5%Manual: 6.25, 12.5, 25, 50mm/s, ±5%Power supply: DC 12V adapter, 7.4V/2000mAh rechargeable lithium batteryWaterproof degree: IPX0Working mode: continuous working Model 2:ECG100G one-channel 12-lead ECG IntroductionECG100G is a kind of single channel electrocardiograph, which features in printing ECG waveform by thermal printing system, prompting for "Lead off" or "Lack of paper", multi-language interface, recording ECG waveform in AUTO/Manual mode, convenient to operate. Function 1)Adopt digital signal processing technology and get high-quality ECG waveform via power frequency filter, baseline filter and EMG filter of ECG signal.2)Adopt high-resolution thermal printing system(8 dot/mm), no need for any adjustments. Recording frequency: up to 150Hz. 3)Real-time and continuously record the clear and accurate ECG waveform and annotation character(including lead mark, sensitivity, paper speed and filter state, etc.).4)In AUTO mode, finish recording by pressing the button once, which improves work efficiency.5)Multi-language (Chinese, English, French, Italian, German, Spanish and Turkish) interface and report.6)In optimal DC state, up to 7-hour standby time, continuous print up to 4-hour, record up to 150 ECG waveform. PerformanceInput mode: floating and defibrillation protectionFrequency response: 0.05Hz ~ 150Hz(-3dB~+0.4dB)CMRR: >60dB, >100dB(add filter)Time constant:≥ 3.2sPatient leak current: <10µACalibration voltage: 1mVSensitivity: 5, 10, 20 mm/mV ±5%, standard sensitivity: 10mm/mV±2%Noise level: ≤15µVp-pInput circuit current: ≤50nAInput impedance: ≥50MΩSampling accuracy: 12-bitSafety classification: class I, type CF and defibrillation-proof applied partRecording mode: thermal printing systemPaper size: 50mm(W)×20m(L)Sampling frequency: 800HzEMG interference filter: 35Hz (-3dB)Power frequency filter: AC 50Hz/60Hz(-20dB)Paper speed: 25, 50mm/s, ±5%Power supply: AC: 100V~240V(50/60Hz)DC: 7.4V/2000mAh rechargeable lithium batteryFuse specification: two AC time lag fuse(φ5×20mm), T1.6AL250VWaterproof degree: IPX0Working mode: continuous working Model 3:ECG300G 3-channel 12-LEADIntroduction ECG300G is an Electrocardiograph which can collect 12-lead ECG signal and print waveform by the thermal printing system. It features in, recording and displaying ECG waveform in AUTO/Manual mode, prompting for “Lead off” and “Lack of paper”, multi-language interface, AC/DC, selecting any rhythm lead, case database management. Function1)Sync collection for 12-lead ECG, adopt digital signal processing technology and get high-quality ECG waveform via power frequency filter, baseline filter and EMG filter of ECG signal.2)Display of 3/6/12-lead ECG, print mode, sensitivity, paper speed and filter state, etc. on one screen, convenient for contrastively diagnosing.3)Multiply printing modes and formats, including manual, auto 4×3, auto 3×4+1, auto 3×4, auto 2×6+1, auto 2×6, auto 3-2+1, auto 3-2, auto 1×12+1, auto 1×12, rhythm 4, rhythm 3 and rhythm 2, etc. Waveform length printed can be adjusted, and with time print function, which meets different requirements.4)Built-in memory stores up to 1000 cases, convenient for case review and statistic.5)Multi-language(Chinese, English, Spanish, Turkish, Polish, Italian, French, German, Portuguese, Kazakstan, Russian, Ukrainian, Serbian and Slovenian) interface and report. Performance Input mode: floating and defibrillation protectionFrequency response: 0.05Hz ~ 150Hz(-3dB~+0.4dB)CMRR: >60dB, >100dB(add filter)Time constant:≥ 3.2sPatient leak current: <10µACalibration voltage: 1mVSensitivity: 2.5, 5, 10, 20, 40 mm/mV ±5%, standard sensitivity: 10mm/mV±2%Noise level: <15µVp-pInput circuit current: ≤50nAInput impedance: ≥50MΩSampling accuracy: 12-bitSafety classification: class I, type CF and defibrillation-proof applied partRecording mode: thermal printing systemAuto record: set record according to auto record format and mode, automatically switching leads, measuring and analyzing.Rhythm record: set record according to rhythm record format and mode, automatically measuring and analyzing.Manual record: set record according to record format, manually switching leads.Measurement parameters: HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1)Paper size: 80mm(W)×20m(L)Sampling frequency: 1000HzEMG interference filter: 25Hz/35Hz (-3dB)Power frequency filter: AC 50Hz/60Hz(-20dB)Paper speed: Auto: 25, 50mm/s, ±5%Rhythm: 25, 50mm/s, ±5%Manual: 5, 6.25, 10, 12.5, 25, 50mm/s, ±5%Power supply: AC: 100V~240V(50/60Hz)DC: 7.4V/3500mAh rechargeable lithium batteryFuse specification: two AC time lag fuse(φ5×20mm), T1.6AL250VWaterproof degree: IPX0Working mode: continuous working Model 4:ECG1200G touch 12-channel 12-leadIntroduction ECG1200G is an electrocardiograph which can collect 12-lead ECG signal simultaneously and print ECG waveform with thermal printing system. It features in, recording and displaying ECG waveform in Manual mode, prompting for “Lead off” and “Lack of paper”, multi-language interface, AC/DC, selecting rhythm lead, printing the trend chart and histogram of P-R interval, case database management. Performance Input mode: floating and defibrillation protection Frequency response: 0.05Hz ~ 150Hz(-3dB~+0.4dB) CMRR: >60dB, >100dB(add filter) Time constant:≥ 3.2s Patient leak current: <10µA Calibration voltage: 1mV Sensitivity: 2.5, 5, 10, 20, 40 mm/mV ±5%, standard sensitivity: 10mm/mV±2% Noise level: ≤15µVp-p Input circuit current: ≤50nA Input impedance: ≥50MΩ Sampling accuracy: 12-bit Safety classification: class I, type CF and defibrillation-proof applied part Recording mode: thermal printing system Paper size: 210mm(W)×20m(L) Sampling frequency: 1000Hz EMG interference filter: 25Hz/35Hz (-3dB) Power frequency filter: AC 50Hz/60Hz(-20dB) Paper speed: Auto: 25, 50mm/s, ±5% Rhythm: 25, 50mm/s, ±5% Manual: 5, 6.25, 10, 12.5, 25, 50mm/s, ±5% Auto record: set record according to auto record format and mode, automatically switching leads, measuring and analyzing. Rhythm record: set record according to rhythm record format and mode, automatically measuring and analyzing. Manual record: set record according to record format, manually switching leads. Measurement parameters: HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1) Power supply: AC: 100V~240V(50/60Hz) DC: 14.8V/3500mAh rechargeable lithium battery Fuse specification: two AC time lag fuse(φ5×20mm), T1.6AL250V Waterproof degree: IPX0 Working mode: continuous workingShipping1. For your earlier and safer to receive the item, please leave us your detail address and telephone number.2. Your item will be sent via Air mail within 48 hours after payment is received. The shipping time is around 2-6 weeks.US buyer 2-5 days delivery. 3. As the usual way, buyer is responsible for the duties, taxes or other VAT or extra charges from the import countries.4.All items will be shipped to buyer's PayPal address. Please confirm your PayPal address is correct before purchase. International Buyers - Please Note:* Import duties, taxes are not included in item price or shipping charges. These charges are buyer's responsibility.* Please check with your country's customs office to determine what these additional cost will be prior to bidding/buying.Terms of SaleBuy Safe Product!The following FDA Disclaimer is required for all eBay listing in Healthcare category and is included for REFERENCE: The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If the item is subject to FDA regulation, We will verify your status as an authorized purchaser of this item before shipping of the item.The Fingertip Pulse Oximeter is registered on the Australian Register of Therapeutic Goods (ARTG) with the code 197923, and certified by FDA of United States and CE,TUV of Europe.The Fingertip Pulse Oximeter that is FDA 510K ApprovedFeedbackPlease leave me a positive feedback if you are satisfied with our products, Your positive feedback will be appreciated,thank you.If you have any problems, please contact us asap before you open a case and leave a negative feedback or ship the item back, we promise we will give you a satisfied answer, thank you for your understanding! Return - After serviceWe offer 60 days return policy. 100% satisfaction is our goal!1.All items are brand new ,with 1 years warranty. 2.If you have a defective item, you want to return or discount. Please contact us within 2 days from you receive the item. 3.We will refund the money to you when we get the return items or replace item for you.4. All return items must be returned with its original package and accessories.About usContec Medical Systems focusing on research, manufacture and distribution of medical instruments,was founded in 1992 as a high-tech company.At present there are more than 1200 employees in our company.Our product line covers a wide range of 13 categories.Most of the domestic hospitals are our customers.Contec hopes to cooperate with international companies to supply more innovative design and advanced technology products.We sincerely welcome you to become one of our global partners.We are looking forward to establishing a successful business relationship with you.Contact usVivian Zhang
Price: 229 USD
Location: Elk Grove Village, Illinois
End Time: 2023-09-17T03:53:28.000Z
Shipping Cost: 0 USD
Product Images
Item Specifics
Restocking Fee: No
Return shipping will be paid by: Buyer
All returns accepted: Returns Accepted
Item must be returned within: 60 Days
Refund will be given as: Money Back
Number of Channels: 1/3/12
ECG & EKG Machine Type: Electrocardiograph
Number of Leads: 12 lead
Country/Region of Manufacture: China
Features: Printer
Operation: Digital
MPN: 69450401
Brand: CONTEC
Available Variations
Color: ECG90A 12 channel
Price: 299 USD
Available Quantity: 100
Quantity Sold: 0
Color: ECG300G
Price: 459 USD
Available Quantity: 91
Quantity Sold: 2
Color: ECG1200G
Price: 699 USD
Available Quantity: 100
Quantity Sold: 0
Color: ECG100G
Price: 229 USD
Available Quantity: 100
Quantity Sold: 0