Description: New in Box Tv-uc253-v Carrier Tru Vu,Advanced Application Controller Fast shipping process with in lower 48 statesWe offer international shipping to CANADA, worldwide TruVu™ Advanced Application ControllerTV-UC253-V The TruVu™ Advanced Application Controller is ideal for HVAC equipment control, advanced air quality control and most zone-level applications. The TV-UC253-V features a built-in flow sensor, dual Ethernet ports with built-in fail-safe that supports direct connection or daisy chain topologies using BACnet/IP and 10 points of onboard control. Designed to operate in a wide range of environmental conditions, it is well suited for mechanical rooms, equipment boxes, or almost any other weather-tight location. Application Features Versatile controller suitable for a variety of applications, including: small AHUs, fan coils, exhaust fans Standard library of control programs available for most unitary equipment and zone applications Supports Carrier communicating room sensors, which allow for local setpoint adjustment and local override Supports Carrier communicating sensors, which are available in a variety of zone and equipment sensing combinations Supports Carrier TruVu touchscreen interfaces for managing and troubleshooting the connected equipment easily and for occupant engagement Supports live, visual displays of control logic, which uses real time operational data and aids in optimizing and troubleshooting system operations Hardware Features Dual 10/100 Mbps, BACnet IP and IP addressing Supports home run, daisy chain and ring IP network topologies Capacitor-backed real-time clock keeps time in the event of power failure or network interruption for at least three days Integral airflow sensor USB port for local device updates, hard-wired, and wireless service connections DIN rail or screw mounting System Features Connects seamlessly to the i-Vu building automation system BACnet Conformance Conforms to the BACnet Advanced Application Controller (B-AAC) and BACnet Broadcast Management Device (B-BBMD) standard device profiles, as defined in BACnet 135-2001 2012 Annex L Protocol Rev 14 Power 24Vac +/- 15% , 50 - 60Hz, 55VA | 24Vdc +/- 10%, 20W. (80VA / 35W if additional Act Net devices are connected) Communication Ports BAS Primary Port: Dual 10/100 BaseT Ethernet ports with built-in fail safe, supporting direct connection or daisy chain topology natively using BACnet/IP (non-routing) Rnet Port: 12Vdc @ 260mA Supports the following: Up to 5 ZS sensors (freely mix ZS zone, ZS duct, ZS immersion and ZS outdoor sensors), iVu Equipment Touch, or TruVu ET Displays (external power required) Act Net Port: Supports up to 5 Act Net communicating devices such as the i-Vu Smart Valves and Smart Damper Kit USB Service Port: For TruVu ET Display support |configuration | wireless service access | firmware updates and controller recovery via USB drive USB Expansion Port: For support of comm expansion devices (future) Inputs Universal: 5 Universal Inputs electronically configurable to any of the following types: Dry | Pulse Counting |Thermistor | 0-10 Vdc Auxiliary Power: 24Vdc @ 100mA total current capacity Integral Airflow Sensor Precision differential pressure sensor 0–2 in. H2O, sensitive down to ±0.001 in. H2O. Barbed tapered airflow connections accept 3/16 in. (4.75 mm) I.D. tubing. Allows for readings across the 0–2in. H2O range, accurate to ±5% of full flow at 2 in. H2O Outputs Universal Output: 1 Output selectable to 0–10 Vdc (20 mA max), 12 Vdc 80 Hz PWM, or (Dry Contact) Rated @24VAC 1 Amp Analog Output: 2 Analog Outputs 10Vdc @ 20mA max (D/A Resolution 12 bits) Digital Output: 2 Digital outputs (Dry Contact) Rated @24Vac/Vdc 1 Amp. Configured normally open Memory 4 GBs eMMC Flash memory and 256 MB DDR3 DRAM. User data is archived to non-volatile flash memory when parameters are changed, every 90 seconds Compliance United States of America: FCC compliant to Title CFR47, Chapter 1, Subchapter A, Part 15,Subpart B, Class B; UL Listed to UL 916, PAZX, Energy Management Equipment RoHS Compliant: 2011/65/EU ANZ: C-Tick Mark AS/NZS 61000-6-3 Canada: Industry Canada Compliant, ICES-003, Class A cUL Listed UL 916, PAZX, Energy Management Equipment, CE mark Real Time Clock Real-time clock keeps track of time in the event of a power failure for at least 3 days Plastic Rating Fire-retardant plastic ABS, UL94-5VA Environmental Operating Range: -22 to 158°F (-30 to 70°C), 10-95% RH, non-condensing Storage: -40 to 158°F (-40 to 70°C), 10-95% RH, non-condensing
Price: 699 USD
Location: San Jose, California
End Time: 2024-12-06T04:00:59.000Z
Shipping Cost: 32 USD
Product Images
Item Specifics
All returns accepted: ReturnsNotAccepted
Brand: Carrier
Model: Tv-uc253-v Carrier