Description: No.1000 Timegrapher Mechanical Watch Timing Tester, Multifunction Professional Watch Timegrapher with LCD Display for Watchmakers Repairers (Black) Feature:Timegrapher NO.1000 is a precise multi-testing instrument for mechanical watches to automatically calculate the rate, amplitude, beat error, and display them by data in real timeLCD Screen to display the frequency diagram of watchesAutomatic adjustment to optimal signal level during testing based on different watchesSampling Periods: 2s, 4s, 6s, 8s, 10s, 20s, 30s, 60s, and the average corresponding period varies with the precise value of the watch6 kinds of testing positions adjustable; Simulation sound to play in the speaker or mute Beat Numbers (Frequency Numbers) Automatic The following beat numbers are selected by automatic selection mode: 12000、14400、18000、19800、21600、25200、28800、36000、43200 (If the tested beat is not in automatically selection, the instrument will display the closest beat number, but the test result is not correct. At this time, use the manual mode to select the relative beat.) Manual selection It can selected out the beat number that automatic selection cannot identify rare beat number. The following beat are selected by manual selection mode: 3600、6000、7200、7380、7440、7800、9000、9100、10800、11880、12000、12342、12480、12600、13320、13440、13500、14000、14040、14160、14200、14280、14400、14520、14580、14760、14850、15000、15360、15600、16200、16320、16800、17196、17258、17280、17786、17897、18000、18049、18514、19332、19440、19800、20160、20222、20944、21000、21031、21306、21600、25200、28800、32400、36000、43200 Lift Angle The lift angle is 52° for many common movements, therefore the lift angle value of instrument for factory is set to 52°. This value is required to calculate the amplitude and must be selected according to the watch movement. The lift angle can be set to between 30°and 70° Specifications - Measuring possibilities: Rate deviation, amplitude, beat error of mechanical watches and diagram recording of the beat noise. - Rate deviation measurement: the range of deviation is ± 999 sec / day, precision 1.0 sec/day. - Amplitude measurement: Numerical display in degrees, resolution is 1°,measuring range: 100°to 360° (the lift angle can affect the amplitude, range: 30°to 70°.Under normal circumstances, the amplitude value do not exceed 360°.) - Measuring of the Beat error (Frequency error): Numerical display in milliseconds. Resolution is 0.1 milliseconds; the measuring range is 0-9.9 ms. - Supply voltage: single-phase AC 100 V~240V ± 10% two-line. - Working environment: 0 ℃ to 50 ℃, relative humidity: 0 to 80% RH - Dimensions: 173×9.5×11.5mm - Weight: 402g Package - 1 * Timegrapher - 1 * Timegrapher Sensor - 1 * US Adapter - 1 * User Manual
Price: 139 USD
Location: Secaucus, New Jersey
End Time: 2025-01-08T06:27:32.000Z
Shipping Cost: 0 USD
Product Images
Item Specifics
Restocking Fee: No
Return shipping will be paid by: Seller
All returns accepted: Returns Accepted
Item must be returned within: 30 Days
Refund will be given as: Money Back
Brand: Unbranded
Type of Tool: Timegrapher